REQUIRED INFORMATION
For firetube boilers in vertical or horizontal position.
Each program is specific to the geometry of a single boiler.
You must enter the name of the boiler in the NAME section, also the position of the boiler vertical or horizontal, the dimensions of the diameter and length of the firebox in centimeters. Also the internal diameter of the fire tube and its spaces or parallel distance between fire tubes, i.e. the distance of each tube in origin X and Y. (more information in the user’s manual).
International standards such as the American Society of Mechanical Engineers and the National Board of Boiler and Pressure Vessel Inspectors produced a study establishing that 79% of the boiler accidents recorded in the three categories of boilers were attributed to only two causes: shutdown due to lack of water, followed by lack of operator qualifications and lack of a good preventive, predictive and corrective maintenance plan. The DIFUALIVER24 tool will help you to calibrate the boiler to keep it in the correct differential pressure range according to its geometrical characteristics of the pyrotubular boiler. Because it is very important the range of high limit and low limit to avoid that the boiler goes beyond the range of excess temperature established by international standards which are from 10 ° C to 30 ° C ie a boiler poorly calibrated and with vulnerabilities in maintenance can rise from excess temperature to higher 30 ° C very quietly but still have water but can cause an accident exploding the boiler or can lower the excess temperature to less than 10 ° C in consequence poor steam quality.
We offer more than a life insurance to your boiler, With “DIFUALIVER24” will keep your boiler in the right overtemperature range avoiding an accident or loss that is possible thanks to our development capacity where each program is specific to the conditions of a single boiler that is if you have more than one boiler will be necessary to acquire several software “DIFUALIVER24” we recommend you to read our offer.
COMPOSITION
There are no more excuses for the boilers have the assertive strategy to find and alert in time any potential danger in the boiler.
It consists of the following offline web software: DIFUALIVER24, TRANSFER, STATUS, HABIT, PITOMETRY and PREDICTIVE-MATRIX.
QUALITY CONTROL
The software is built with the world’s most advanced, complete and secure language “JavaScript”. This language is used to control space rockets. Applicable for predictive, preventive or corrective maintenance. Adjust, monitor and control water level, pressure differential, excess temperature, burner power, steam production, water surface tension, heat transfer, blowdown percentage, condensate return, pH level, actual status of your boiler and amount of scale. We are not in favor of performing hydrostatic tests every year because this practice shortens the life of the boiler, but it is not an exception. YUNUS CENGEL thermodynamic values are used. If you need to use other values, please let us know.
INSTRUMENTS OPTIONLS
Gas detector, dissolved oxygen (DO) detector, dissolved solids detector (TDS), pH meter, thermograph.