REQUIRED INFORMATION
DIFUALIVER24 THERMAL is carried out in 3 phases PRE, CALIBRE and SAFE.
Each program is specific to the geometry of a single boiler.
For thermal oil boilers with serpertin in vertical or horizontal position with horizontal expansion tank.
You must write the name of the boiler in the NAME section, also the position of the vertical or horizontal serpertin, the dimensions of the expansion tank in centimeters diameter and length. Also the internal diameter of the serpertin and its spaces or distance between oil tubes. If the oil serpertin tube is in horizontal position take the measurements in centimeters of the serpertin distances horizontally but if the oil serpertin tube is in vertical position take the measurements in centimeters of the serpertin distances vertically (more information in the user’s manual).
International standards such as the American Society of Mechanical Engineers and the National Board of Boiler and Pressure Vessel Inspectors produced a study establishing that 79% of the boiler accidents recorded in the three categories of boilers were attributed to only two causes: shutdown due to lack of water, followed by lack of operator qualifications and lack of a good preventive, predictive and corrective maintenance plan. The DIFUALIVER24
will allow you to vary the geometric dimensions of the dome or expansion drum of the thermal boilers, its temperature, the flow range, all this in order to design or manufacture boilers that are maintained in the range to prevent the boiler from exceeding the range of excess thermal differential (thermal jump) established according to the thermal fluid between 18 ° C to 22 ° C and the service temperature of the system between 36 ° C to 42 ° C, that is to say, a boiler badly calibrated and with vulnerabilities in the maintenance can raise the excess of thermal differential to more than 40 °C shortening the useful life of the oil and requiring a greater economic cost in the installation and greater electrical consumption with greater pipe diameters or it can lower the excess of thermal differential to less than 15 °C in consequence it will obtain a cooling in the system.
With “DIFUALIVER THERMAL” the thermodynamics can be evaluated as a function of the geometry of the design under test.
We offer more than a life insurance to your boiler, With “DIFUALIVER24” will keep your boiler in the right overtemperature range avoiding an accident or loss that is possible thanks to our development capacity where each program is specific to the conditions of a single boiler that is if you have more than one boiler will be necessary to acquire several software “DIFUALIVER24” we recommend you to read our offer.
COMPOSITION
There are no more excuses for the boilers have the assertive strategy to find and alert in time any potential danger in the boiler.
It consists of the following offline web software: DIFUALIVER24, TRANSFER, STATUS, HABIT, PITOMETRY and PREDICTIVE-MATRIX.
QUALITY CONTROL
The software is built with the world’s most advanced, complete and secure language “JavaScript”. This language is used to control space rockets. Applicable for predictive, preventive or corrective maintenance. Adjust, monitor and control water level, pressure differential, excess temperature, burner power, steam production, water surface tension, heat transfer, blowdown percentage, condensate return, pH level, actual status of your boiler and amount of scale. We are not in favor of performing hydrostatic tests every year because this practice shortens the life of the boiler, but it is not an exception. YUNUS CENGEL thermodynamic values are used. If you need to use other values, please let us know.
INSTRUMENTS OPTIONLS
Gas detector, dissolved oxygen (DO) detector, dissolved solids detector (TDS), pH meter, thermograph.